본문 바로가기 대메뉴 바로가기
이정일 교수

Jungil Lee

INFO

  • 소속캠퍼스한국원자력연구원
  • 연락처042-868-2315
  • 출신전공물리학
  • 학위박사
  • 최종출신대학경상대학교
  • 이메일

연구분야

방사선량 측정 및 평가

Radiation measurement and dosimetry

대표연구실적

-  J.I.Lee, I. Chang, A.S.Pradhan, J.L.Kim, B.H.Kim, K.S.Kim, On the use of new generation mobile phone (smart phone) for retrospective accident dosimetry, Radiation Measurements 116 (2015) 151-154 -  J.I.Lee, J.S.Yang, J.L.Kim, A.S.Pradhan, J.D.Lee, K.S.Chung and H.S.Choe, Dosimetric characteristics of LiF:Mg,Cu,Si thermoluminescent materials, Applied Physics Letters 89 (2006) 094110 -  J.I.Lee, A.S.Pradhan, J.L.Kim, I. Chang, B.H. Kim, K.S.Chung, Characteristics of LiAlO2-Radioluminescence and optically stimulated luminescence

논문(최근 5년)

-  Characteristics of LiAlO2 - Radioluminescence and optically stimulated luminescence[ RADIATION MEASUREMENTS,2013-03-01] -  Thermoluminescence glow curve deconvolution of LiF:Mg,Cu,Si with more realistic kinetic models[ RADIATION MEASUREMENTS,2013-03-01] -  TL response of pairs of 6LiF:Mg,Cu,Si/7LiF:Mg,Cu,Si and TLD-600/TLD-700 to 0.1-12 MeV neutrons[ RADIATION MEASUREMENTS,2013-03-01] -  Response of six neutron survey meters in mixed fields of fast and thermal neutrons[Radiation Protection Dosimetry,2013-03-01] -  Environmental gamma-ray dose rate measurement by using ultra-high sensitive LiF:Mg,Cu,Si TLD[ RADIATION MEASUREMENTS,2013-03-01] -  Effect of pre-irradiation annealing treatments on the response of high-temperature glow peaks of LiF:Mg,Ti[ RADIATION MEASUREMENTS,2014-03-01] -  Fast neutron calibration fields constructed using a proton accelerator of KIRAMS and spectrum-weighted response of varous neutron detectors[Radiation Protection Dosimetry,2014-03-01] -  Spectrum weighted responses of several neutron detectors[Nuclear Engineering and Technology,2014-03-01] -  Fast assessment of retrospective dosimetry using the SAAD-POSL method with core disc samples from building materials[ RADIATION MEASUREMENTS,2014-03-01] -  An algorithm for unified analysis on the thermoluminescence glow curve[ RADIATION MEASUREMENTS,2014-03-01] -  Properties of lithium aluminate for applicationas an OSL dosimeter[Radiation Physics and Chemistry,2014-03-01] -  On the use of new generation mobile phone (smartphone) for retrospective accident dosimetry[Radiation Physics and Chemistry,2015-03-01] -  Fading test using the SAAD-POSL method for retrospective accidental dosimetry of building materials[Radiation Physics and Chemistry,2015-03-01] -  An algorithm for the integrated deconvolution of radioluminescence and thermally/optically stimulated luminescence glow curves[ RADIATION MEASUREMENTS,2015-03-01] -  252Cf 중성자장에서 열형광선량계(TLD)를 이용한 중성자 방사선량 측정[대한방사선방어학회지,2013-03-01] -  열자극발광 및 광자극발광 측정장치의 개발[대한방사선방어학회지,2015-03-01]

특허(최근 5년)

-  광자극발광물질의 제조방법[2013-11-28] -  결정성장제어프로그램[2013-12-20]